LASER - Hair Removal 808,Professional 80W Ice-Cooling Laser Hair Removal,808nm Gold Wavelength Laser.Painless & Permanent
- days
- :
- hours
- :
- min
- :
- sec
- * 【808nm Golden Wavelength, Precisely Targets Hair Follicles】Utilizes medical-grade 808nm semiconductor laser. This wavelength is most efficiently absorbed by melanin, allowing it to precisely penetrate to the hair follicle root, thoroughly destroying its regenerative ability while avoiding damage to the surrounding skin, achieving safe and efficient hair removal.
- * 【Sapphire Ice-Cooling System for a Painless, Comfortable Experience】Integrates a contact sapphire cooling tip and a semiconductor cooling system. It continuously cools the epidermis before, during, and after laser emission, effectively neutralizing the heat sensation and significantly improving comfort. It eliminates the burning pain of traditional hair removal, achieving a truly "ice-cool, painless" experience.
- * 【80W High Power & Professional-Grade Configuration】Equipped with an ultra-high 80W optical power VCSEL laser, delivering concentrated and stable energy to ensure deep hair follicles are effectively destroyed. The desktop design provides continuous power, matching the effectiveness of professional salon equipment, allowing you to enjoy clinic-grade permanent hair removal results at home.
- * 【Easy, Efficient Operation for Full-Body Use】Features both "Stamp" and "Glide" modes to easily handle large and small areas. Legs take only about 15 minutes, while delicate areas like lip hair can be finished in about 5 minutes. One device tackles unwanted hair on limbs, underarms, bikini line, lips, and more across the whole body.
- * 【Safe and Reliable】Based on the scientific and reliable principle of Selective Photothermolysis. After a course of 5 or more treatments (with 2-3 week intervals between sessions), permanent hair reduction can be achieved. It is safe and does not damage the skin, nor does it affect sweat gland function.
Water must be added before use.
1. Remove the water funnel and connect it to the water inlet on the back of the device.
2. Add purified or distilled water until water flows from the overflow outlet.
Note: Only purified or distilled water must be used; tap water or other types of water must not be used.
How to use?
1. Power on: Connect the power cord and turn on the power switch; the screen will light up.
2. Shave: Before operation, perform a manual shaving process, leaving 1-2mm of hair to facilitate light absorption.
3. Apply cooling gel: Apply a small amount of cooling gel, about the thickness of a coin, to the treatment area. Do not apply too thickly, otherwise it will affect the effect.
4. Adjust treatment parameters: Select the appropriate operating parameters according to your skin tone, hair thickness, and the area to be treated.
5. Operation Process:
(1) Slide the handle probe slowly to operate, ensuring it fits snugly against the skin to avoid light leakage.
(2) Energy Adjustment: Start with energy level 4. If the heat is too intense, reduce the energy.
Tips:A slight feeling of heat expansion indicates that the melanin is absorbed by the 808nm laser, converting light energy into heat energy, which destroys the melanin in the hair follicle. This is the optimal effect.
6. Skin Cooling: After operation, allow the treated area to cool naturally for 3-5 minutes.
7. Skin Cleansing: After 5 minutes of natural cooling, remove the gel and apply a moisturizing product.
8. Power Off: Turn off the power switch and unplug the power cord.
Operation Precautions
1. Never look directly at the strong light emitted from the front of the laser handle.
2. Slide the handle slowly during operation. Do not stop in one place and emit light too many times consecutively to avoid skin discomfort.
Operation Time: Once every 15-20 days.
Post-Hair Removal Precautions
1.Avoid hot water baths for 7 days after hair removal. Warm water is sufficient.
2. Avoid spicy, alcoholic, and stimulating foods.
3. Avoid excessive sun exposure; use sunscreen and a makeup base.
4. After hair removal, avoid shaving manually; complete a full course of treatment (5-6 sessions per course).
Instrument Maintenance Precautions
1. It is recommended to change the water to purified or distilled water every month.
2. The instrument should be placed in a clean, well-ventilated room with a temperature of 5-40°C and humidity not exceeding 80%, avoiding direct sunlight.
3. During use, ensure that the instrument's ventilation openings are not blocked, and that there is at least 5cm of space around the instrument.
4. Do not move the instrument over long distances. Before transportation, all water inside the instrument must be drained, and the instrument must be transported using the original manufacturer's shock-absorbing packaging.
Contraindications
1. People with open wounds should avoid operating on wounds or suspend operation.
2. Pregnant women, breastfeeding women, and women during menstruation are prohibited from operating the instrument.
3. People with metal or silicone implants, drug pumps, defibrillators, pacemakers, nerve stimulators, or electronic devices are prohibited from operating the instrument.
4. People who have had abdominal surgery within the past three months or have bleeding at the operating site are prohibited from operating the instrument.
5. People with epilepsy are prohibited from operating the instrument. 6. Patients with heart disease or arrhythmia, especially those with a pacemaker, are prohibited from undergoing this procedure.
7. Patients with cancer or malignant tumors are prohibited from undergoing this procedure.
8. Patients with acute inflammation or infectious diseases are prohibited from undergoing this procedure.
9. Patients with other serious illnesses, such as gastric ulcers, duodenal ulcers, hypertension, diabetes, and severe stomach ailments, are prohibited from undergoing this procedure.
Specifications:
Input voltage:AC 100~240V 50~60Hz
Input current:AC 3.2A~1.3A
Maximum power:320W
Optical power:80W
Spot area:0.9CM²
Energy:18-26J
Frequency range:1~5Hz
Strength range:1~10
Working mode:Stamp/scan
Refrigeration control range:0~5
Number of turns:60 million rounds
Product size:31*24*20cm
Product weight:3600g
Package size:43*35*26cm
Package weight:7500g
Packing List:
Hair Removal Devices*1
Water-filling Funnel *1
Power Cord*1
Instruction Manual*1
Safety Glasses*1